The TellyLabs kit is a vacuum-based sample collection device. Skin prep and proper device placement are essential to success.
Drink a glass of water before you do anything else.
Wash your hands with soap.
Jumping jacks or squats are both great exercises to warm your hands and get your blood flowing, which will make collection easier. Please avoid strenuous workouts for 24 hours before collection.
Remove all contents from the box.
Remove the TellyLabs device from the packaging. Unscrew the tube cap and press the tube into the end of the device. Use a slight twist for a secure fit.
Note: A small gap will remain after tube is installed.
Locate a flat area on the outside of your arm at least 5 fingers from the top of your shoulder.
(Optional) Use the provided razor to remove excess hair from the shoulder region where the device will be applied.
Activate the heat pack by bending the coin back and forth. You will hear a click and the gel inside will slightly change color. Place the heat pack vertically on the upper arm for two minutes.
Note: The heat pack may be taken on and off if the temperature becomes uncomfortable.
Clean your non-dominant shoulder with the provided alcohol pad to disinfect and remove oils, make sure the alcohol dries before proceeding to the next step.
Peel the paper off the bottom of the device using the tab on the back of the device.
Stick the device FIRMLY to the center of the heated portion of your arm with the tube facing down.
Note: The adhesive’s main role is to maintain the device’s stored vacuum once activated.
To activate, press the lever down while bracing the device.
Note: Movement during activation can break the seal and lead to failure.
The button on the device will turn green to indicate the draw has started.
The flow of blood may take between 30-90 seconds to begin. Shown below is a timelapse over 60 seconds after blood flow has started. The actual process is slow and calming and should not last longer than 7 minutes at most. WARNING: Blood is shown in following images and videos below.
Remove the device by peeling it off your arm after 7 minutes OR after 500 mL of blood has been drawn.
Use the provided gauze to wipe the blood from the collection site.
Apply a bandage to the collection site.
Remove the tube by gently pulling and twisting the tube off of the device.
Press the cap onto the tube firmly until a click is heard.
Flip the tube 10 times to mix contents.
After use, wash your hands with warm water and soap.
Place the sample into the plastic specimen bag and seal.
Place the bag(s) into the same box your kit came in and close the box. Then, place the box into the return mailer.
Place the package outside. Please text a picture of the package to (888) 200-1228. This will help us to coordinate the pickup.
Note: You can also return directly at an indoor FedEx location. Do not use drop boxes as these get extremely hot during the day
Once you have finished collecting your sample and packaging it for return, you will follow the prompts online and submit electronically. The return shipping will follow.